{"product_id":"jackel-e-series-rubber-pipe-hub-sump-basin","title":"Jackel E-Series Rubber Pipe Hub for Sump Basins (1\" to 2\")","description":"\u003ch2\u003eWater-tight pipe seal for sump and sewage basins\u003c\/h2\u003e\n\u003cp\u003eThe Jackel E-Series hub seals the point where a pipe passes through a sump or sewage basin. It is moulded from flexible PVC, so it compresses around the pipe and seals on contact. No caulking, no sealant, no cure time. Pick your pipe size, lubricate the hub, and push the pipe through.\u003c\/p\u003e\n\u003cp\u003eThese are the same hubs supplied with the \u003ca href=\"\/products\/jackel-sump-dome-radon-basin-cover\"\u003eJackel Radon\/Sump Dome (SMR16101-CV)\u003c\/a\u003e. Sold individually here so you can replace one that has gone missing, or fit the pipe size your kit did not cover.\u003c\/p\u003e\n\n\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo caulking required.\u003c\/strong\u003e The flexible PVC body forms a water-tight seal on contact. Nothing to mix, nothing to wait on, nothing to clean up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Schedule 40 and Schedule 80.\u003c\/strong\u003e One hub covers both wall thicknesses at the same nominal pipe size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast to install.\u003c\/strong\u003e Lubricate and push the pipe through. The part is moulded with \"LUBRICATE TO INSTALL\" right on it as a reminder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServiceable.\u003c\/strong\u003e Pull the pipe later and the hub is still usable. A caulked penetration has to be cut out and redone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in the USA\u003c\/strong\u003e by Jackel Eco-Systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eChoose your size\u003c\/h3\u003e\n\u003cp\u003eMatch the hub to the \u003cstrong\u003enominal pipe size\u003c\/strong\u003e, not to the diameter of the hole in the basin.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize you select\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eJackel part\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFits\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003eE100H\u003c\/td\u003e\n\u003ctd\u003e1\" Schedule 40 or 80 pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd\u003eE125H\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\" Schedule 40 or 80 pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd\u003eE150H\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" Schedule 40 or 80 pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003ctd\u003eE200H\u003c\/td\u003e\n\u003ctd\u003e2\" Schedule 40 or 80 pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJackel Eco-Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE100H, E125H, E150H, E200H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchedule 40 and Schedule 80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompression, water tight, no caulking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePipe penetration through a sump or sewage basin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSold as\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhere this fits in a radon system\u003c\/h3\u003e\n\u003cp\u003eWhen a sump pit is used as the suction point for an active sub-slab depressurization system, every opening into that pit matters. A pipe penetration left open bleeds away suction and gives soil gas a path into the basement. The E-Series hub closes that penetration so the pit can hold pressure.\u003c\/p\u003e\n\u003cp\u003eTo be precise about what each part does: Jackel rates the E-Series hub as a \u003cem\u003ewater-tight\u003c\/em\u003e seal. The gas-tight element of a sealed sump assembly is the \u003ca href=\"\/products\/jackel-sump-dome-radon-basin-cover\"\u003esump dome cover\u003c\/a\u003e itself. And sealing on its own is not mitigation. Active sub-slab depressurization is the method that lowers radon levels, measured against Health Canada's guideline of 200 Bq\/m³ (5.4 pCi\/L).\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich size do I need?\u003c\/strong\u003e\u003cbr\u003eMatch the nominal size of the pipe passing through the basin, not the hole diameter. A 1-1\/2\" pipe takes the 1-1\/2\" hub (E150H).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need caulk or sealant with it?\u003c\/strong\u003e\u003cbr\u003eNo. Jackel specifies the hub as a water-tight seal with no caulking. Lubricate it to install and that is the whole job.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it work with Schedule 80 pipe?\u003c\/strong\u003e\u003cbr\u003eYes. Each hub fits both Schedule 40 and Schedule 80 at its nominal size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the same hub that comes with the Jackel sump dome?\u003c\/strong\u003e\u003cbr\u003eYes. The SMR16101-CV kit ships with one each of E100H, E125H, E150H and E200H. This listing sells them individually.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you ship within Canada?\u003c\/strong\u003e\u003cbr\u003eYes. Radon Depot is a Canadian supplier shipping domestically, so no cross-border brokerage or customs paperwork on the way to you.\u003c\/p\u003e","brand":"Jackel","offers":[{"title":"1\"","offer_id":49135698804991,"sku":"JACKEL-E100H","price":27.95,"currency_code":"CAD","in_stock":true},{"title":"1-1\/4\"","offer_id":49135698837759,"sku":"JACKEL-E125H","price":27.95,"currency_code":"CAD","in_stock":true},{"title":"1-1\/2\"","offer_id":49135698870527,"sku":"JACKEL-E150H","price":27.95,"currency_code":"CAD","in_stock":true},{"title":"2\"","offer_id":49135698903295,"sku":"JACKEL-E200H","price":27.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/6639\/0015\/files\/jackel-e100h-pipe-hub-1-inch.jpg?v=1788290727","url":"https:\/\/radondepot.ca\/products\/jackel-e-series-rubber-pipe-hub-sump-basin","provider":"Radon Depot","version":"1.0","type":"link"}