RadonAway Condensate Bypass Kit for 4" Transition Fitting (25030)
$29.99 flat shipping anywhere in Canada · Shipping details
PRO Installer or contractor? Get trade pricing
RadonAway Condensate Bypass Kit for 4" Transition Fitting (25030) is backordered and will ship as soon as it is back in stock.
Shipping & Delivery
Shipping & Delivery
Flat-rate shipping anywhere in Canada: $29.99 per order for most products, $15 for radon test kits. Heavy freight items show their own rate under the price. All orders ship from within Canada, so there are no customs delays or cross-border fees. Full shipping details
Returns & Warranty
Returns & Warranty
Items may be returned within 30 days of receipt in original, unused condition. RadonAway Pro Series fans carry a 5-year manufacturer warranty. Contact us for warranty claims.
Description
Description
RadonAway Condensate Bypass Kit for 4" Transition Fitting (25030)
Routes condensation from a radon exhaust pipe around the fan, using a 4" transition fitting installed above the fan.
Water condenses inside a radon exhaust pipe and runs back down toward the fan. RadonAway fan motors are built to handle moisture, but RadonAway says that in some locations and weather a bypass is worth adding to cut down on possible fan damage. This kit catches the water above the fan and drains it through an insulated tube to the inlet pipe below, so it bypasses the motor.
This kit is made for a 4" Schedule 40 PVC transition fitting (RadonAway 13245), which is sold separately and not carried by RadonDepot. The weir in the kit sits inside that fitting.
What is in the kit
- 1 weir for the transition fitting
- 2 barbed fittings, for 3/8" tube and 1/4" NPT
- 1 clear 3/8" tube, 3 ft long
- 1 tubing insulation, 3 ft long
Specifications
| Part number | 25030 |
| For use with | 4" Schedule 40 PVC transition fitting (RadonAway 13245, sold separately) |
| Tubing | 3/8" clear tube, 3 ft |
| Fittings | Barbed, 1/4" NPT |
| Manufacturer | RadonAway |
You will also need
- A 4" transition fitting (RadonAway 13245)
- A drill with at least a 3/8" chuck, a 7/16" drill bit and a 1/4"-18 NPT tap
- An adjustable wrench
- PVC cement
Installation notes (from RadonAway's instructions)
- Cement the weir into the transition fitting, then install the transition fitting above the fan
- Drill and tap a 1/4"-18 NPT hole in the transition fitting and thread in a barbed fitting, with PVC cement on the threads
- Do the same on the inlet pipe below the fan, less than 36" from the upper fitting
- Fit the tubing and insulation to both barbed fittings
- Cut the tubing as short as practical and route it as straight as possible, with no kinks
Condensate bypass kit or fan guard?
| Condensate Bypass Kit (25030) | Fan Guard (76040-2) | |
|---|---|---|
| What it does | Drains water from the exhaust pipe around the fan | Drains water from the exhaust pipe around the fan |
| Where the water is collected | In a 4" transition fitting above the fan, using the kit's weir | In the fan guard's own drain fitting |
| Other parts needed | A 4" transition fitting (RadonAway 13245), sold separately | None |
| Tools | 7/16" drill bit, 1/4" NPT tap | 7/16" drill bit, 1/4" NPT tap |
If your system does not have a transition fitting, the RadonAway Fan Guard is a complete kit on its own. Not sure which suits your system? Contact us and we will help.
Common questions
Is this the same as the fan guard?
No. They are two different RadonAway parts that do the same job in different ways. The fan guard has its own drain fitting. This kit goes into a transition fitting.
Can I use it without the transition fitting?
RadonAway's instructions are written for the 4" transition fitting (13245), and the weir is shaped to sit inside it.
Do I need to drill the pipe?
Yes. Both barbed fittings thread into tapped 1/4" NPT holes, one above the fan and one below.
Payment & Security